Inverter Horizontals

HORIZONTALS PARIS INVERTER is an efficient and reliable solution for air handling purposes. The units are available in heat pump or cooling only for air conditioning of medium areas, such as manufacturing plants, warehouses, offices, supermarkets and shops.

The range has been designed for indoor installation and and to be ducted to both the indoor area to be air conditioned and outside for heating and cooling rejection, ideal for ceiling applications.

HORIZONTALS PARIS INVERTER

MODEL  i - PAR018i - PAR025
COOLING MODE SYSTEM
Total cooling power _ NOMINALPCkW18.624.5
Total cooling power _ MAXIMUMPCkW21.028.0
Coefficient of energy efficiency in cooling _ NOMINALEERW/W2.752.80
Coefficient of energy efficiency in cooling _ MAXIMUMEERW/W2.452.51
Seasonal energy efficiency ηs,c%149.7171.6
HEATING MODE SYSTEM
Total heating power _ NOMINALPHkW19.024.6
Total heating power _ MAXIMUMPHkW22.729.6
Coefficient of energy efficiency in heating _ NOMINALCOPW/W3.133.22
Coefficient of energy efficiency in heating - MAXIMUMCOPW/W2.882.98
Seasonal energy efficiency ηs,h%128.7136.9
COMPRESSORS
Type of compressorBrushless DC InverterBrushless DC Inverter
Expansion valveElectronicElectronic
EXTERIOR UNIT FAN
Fan TypeCentrifugal ECCentrifugal EC
Airflowqem³/h60007750
Available static pressure of equipmentpedPa160246
INTERNAL UNIT FAN
Fan TypeCentrifugal ECCentrifugal EC
Airflowqim³/h38004500
Available static pressure in equipmentpedPa300484
GENERAL CHARACTERISTICS
Power supply400V-III+N-50Hz400V-III+N-50Hz
RefrigerantR410AR410A
Colling power at nominal conditions of internal temperature of DBT= 27ºC, WBT = 19ºC and an external temperature of DBT = 35ºC, in accordance with UNE-EN 14511 standard

Heating power at nominal internal temperature conditions of DBT = 20ºC, WBT = 15ºC max., And an external temperature of DBT = 7ºC, WBT = 6ºC, in accordance with UNE-EN 14511 standard