Inverter verticals

  • i-NYC Inverter Better EN

  • i-NYC Inverter CA

  • i-NYC Inverter Control EN

The i-NYC INVERTER vertical series are highly efficient air conditioning units with heat pump or only cooling for medium and high capacity applications such as supermarkets, entertainment areas, shops, production plants, offices or malls.

These vertical construction units are designed to be installed inside buildings, normally in machine rooms and to be joined to a network of ducts inside (zone to be air-conditioned) and outside (heat dissipation).

The i-NYC series, goes from 13 to 92 kW, are available in a compact and split version. Full configurable and with a wide range of options, they are the ideal invisible solution for buildings where units cannot be installed outdoors.

The Inverter compressor allows to precisely adjust the capacity of the equipment to a specific thermic demand of the installation, consuming only the necessary electrical capacity at all times.

All our equipments complies with the most demanding regulations of the energy certification (ERP2021).

VERTICALS NEW YORK INVERTER

MODEL i-NYC025i-NYC040i-NYC050i-NYC065iNYC090
COOLING MODE SYSTEM
Total nominal cooling capacity / max.kW22,9 / 26,236,3 / 41,543,0 / 50,261,9 / 66,085,6 / 92,0
Nominal sensible cooling capacity / max.kW17,9 / 19,228,3 / 30,432,3 / 36,448,9 / 50,763,1 / 67,0
Useful absorbed capacity in nominal cooling / max.kW8,9 / 11,212,0 / 15,213,0 / 16,919,8 / 21,928,3 / 31,8
EER (nominal)/ max.W/W2,58 / 2,353,03 / 2,733,30 / 2,973,12 / 3,013,02 / 2,89
ESEER (cooling)W/W3,493,674,663,963,82
Seasonal energy efficiency (cooling)%140147186158153
HEATING MODE SYSTEM
Total nominal heating capacity / max.kW23,5 / 28,737,2 / 44,444,1 / 52,463,5 / 68,388,0 / 98,6
Useful absorbed capacity in nominal heating / max.kW8,0 / 10,210,7 / 13,811,5 / 15,117,6 / 19,625,7 / 29,1
COP (nominal) / max.W/W2,94 / 2,813,47 / 3,223,83 / 3,483,60 / 3,483,43 / 3,38
ESEER (Heating)W/W4,174,434,854,374,09
Seasonal energy efficiency (heating)%164174191172161
COMPRESSORS
Type of compressorsScroll Inverter DC
Total number of compressorsud.1
INTERNAL FAN UNIT
Fan typeEC Centrifugal
Air flowm3/h5.0007.5007.00013.00014.000
Total useful absorbed capacity of the fanskW0,911,571,232,142,78
Available static pressure of equipment (max.)Pa874290470543424
EXTERNAL FAN UNIT
Fan typeCentrifugal ECRadial ECRadial ECRadial ECRadial EC
Air flowm3/h8.00011.60014.00022.50025.500
Total useful absorbed capacity of the fanskW1,821,441,222,583,52
Available static pressure of equipmentPa196475368696676
DIMENSIONS AND WEIGHTS (Std. Equipment)
Widthmm14301780272027202720
Depthmm9841050938938938
Highmm20152398245524552455
Weigthkg610710790830880
Colling power at nominal conditions of internal temperature of DBT= 27ºC, WBT = 19ºC and an external temperature of DBT = 35ºC, in accordance with UNE-EN 14511 standard

Heating power at nominal internal temperature conditions of DBT = 20ºC, WBT = 15ºC max., and an external temperature of DBT = 7ºC, WBT = 6ºC, in accordance with UNE-EN 14511 standard