Horizontals

autónomo horizontal inverter rc clima cerezo

I-PAR INVERTER Horizontals are high-efficiency air conditioning units with heat pump or cold-only operation, for medium-capacity places such as shops, industries, offices or supermarkets.

These horizontal units are designed to be installed inside buildings, usually in false ceilings, and to be coupled to a network of ducts to the interior (area to be air conditioned) and to the exterior (heat dissipation).

The i-PAR range, from 10 to 30 kW, is available in a compact, or split version. Fully configurable and with a wide range of options, they are the ideal invisible solution for buildings where units cannot be installed outdoors.

The Inverter compressor allows to precisely adjust the capacity of the equipment to the thermal demand of the installation, consuming only the necessary electrical power at all times.

Every unit complies with the most demanding energy regulations (ERP2021).

HORIZONTALS PARIS INVERTER

MODEL  i - PAR018i - PAR025
COOLING MODE SYSTEM
Total cooling power _ NOMINALPCkW18.624.5
Total cooling power _ MAXIMUMPCkW21.028.0
Coefficient of energy efficiency in cooling _ NOMINALEERW/W2.752.80
Coefficient of energy efficiency in cooling _ MAXIMUMEERW/W2.452.51
Seasonal energy efficiency ηs,c%149.7171.6
HEATING MODE SYSTEM
Total heating power _ NOMINALPHkW19.024.6
Total heating power _ MAXIMUMPHkW22.729.6
Coefficient of energy efficiency in heating _ NOMINALCOPW/W3.133.22
Coefficient of energy efficiency in heating - MAXIMUMCOPW/W2.882.98
Seasonal energy efficiency ηs,h%128.7136.9
COMPRESSORS
Type of compressorBrushless DC InverterBrushless DC Inverter
Expansion valveElectronicElectronic
EXTERIOR UNIT FAN
Fan TypeCentrifugal ECCentrifugal EC
Airflowqem³/h60007750
Available static pressure of theequipmentpedPa160246
INTERNAL UNIT FAN
Fan TypeCentrifugal ECCentrifugal EC
Airflowqim³/h38004500
Available static pressure in the equipmentpedPa300484
GENERAL CHARACTERISTICS
Power supply400V-III+N-50Hz400V-III+N-50Hz
RefrigerantR410AR410A
Cooling power at nominal conditions of internal temperature of DBT= 27ºC, WBT = 19ºC and an external temperature of DBT = 35ºC, according to UNE-EN 14511 standard.

Heating power at nominal internal temperature conditions of DBT = 20ºC, WBT = 15ºC max., and an external temperature of DBT = 7ºC, WBT = 6ºC, according to UNE-EN 14511 standard.